Ultra-DekŪ SPECIAL ERECTION
TECHNIQUES
MID SLOPE FIXED
CONDITION

NOTES:
- This special detail is for use when a panel run exceeds the thermal
movement capabilities of the panel clip. Please refer to page UD-3.
- A positive panel attachment is made at the mid-point in the panel run
allowing for thermal movement to the eave and ridge.
- The standard floating ridge condition must be used in conjunction with
this special eave detail.
- The floating eave plate must be used to allow for panel movement at the
eave.
- Floating clips have a maximum movement of 1" in each direction. Articulating
clips have a maximum movement of 1 1/4" in each direction. Thermal calculations
must be performed for each project to ensure that the thermal movement of
the roof will not exceed the design of the clips and slot in the special eave
plate.
Back Next