| Table of Contents(Page UD-16) |
ERECTION SEQUENCE Ultra-Dek®
|
2.05 PREFABRICATED ROOF JACKS A. Pipe flashings shall be a one piece [# choose one: EPDM (ethylene propylene diene monomer) molded rubber boot having a serviceable temperature range of -60°F to 270°F (for standard applications) or neoprene molded rubber boot having a serviceable temperature range of -45°F to 250°F (for exposure to petrochemicals) or silicone molded rubber boot having a serviceable temperature range of -100°F to 450°F (for high temperature applications)] and shall be resistant to ozone and ultraviolet rays. Units shall have an aluminum flanged base ring. Do not install pipe flashings through any panel seams - install ONLY in the flat portion of the panel. PART 3 - EXECUTION A.
Examination: B.
Discrepancies: 3.02 INSTALLATION A. Install metal roof system so that it is weathertight, without waves, warps, buckles, fastening stresses or distortion, allowing for expansion and contraction. B. Install metal roof system in accordance with manufacturer’s instructions and shop drawings. C. Provide concealed anchors at all panel attachment locations. D. Install panels plumb, level and straight with seams and ribs parallel, conforming to design as indicated. 3.03 ROOF CURB INSTALLATION A. Comply with metal roof system manufacturer’s approved shop drawings, instructions and recommendations for installation of roof curbs. Refer to metal roof system manufacturer’s standard installation details. Anchor curbs securely in place with provisions for thermal and structural movement. 3.05 CLEANING, PROTECTION A. Dispose of excess materials and remove debris from site. |
B. Clean work in accordance with manufacturer’s recommendations. C. Protect work against damage until final acceptance. Replace or repair to the satisfaction of the architect (owner), any work that becomes damaged prior to final acceptance. D. Touch up minor scratches and abrasions. E. Do not allow panels or trim to come into contact with dissimilar metals such as copper, lead, graphite or cast iron. Water run-off from these materials is also prohibited. This specifically includes condensate from roof top A/C units. END OF SECTION
DISCLAIMER: ASBC makes no warranty, express or implied, as to the merchantability or fitness for any particular purpose of any product manufactured by an optional manufacturer. If you choose to use a product manufactured by an optional manufacturer, as defined herein, you take the product as is and at your own risk Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. ASBC reserves the right to discontinue products at any time or change specifications and/or designs without notice and without incurring obligation. |