SSR SYSTEMS PRICING

←Previous Page Next Page →

Page SSR-34

Table of Contents

ITEM

DESCRIPTION PRICE PER EACH

RIDGE FLASHING FLOATING

Specify Roof Pitch

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-200 3 1/2" 10'-2" 15 1/2" 10.63# 1/4-2 1/2:12 41.33 43.07 55.13 61.76
FL-202 4 1/2" 10'-2" 17 1/2" 12.00# 2 9/6-4:12 44.72 47.01 60.58 67.92

NOTE: For use without ventilator - 18’ peak purlin spacing.

FL-213  6 1/2" 10'-2" 21 1/2" 14.74# 1/4-2 1/2:12 50.53 53.72 70.42 79.66
FL-214 7 1/2" 10'-2" 23 1/2" 16.17# 2 9/16-4:12 54.08 57.82 75.98 85.90

NOTE: For use without ventilator 24" peak purlin spacing.

FL-205 10 1/4" 10'-2" 29" 19.88# 1/4-2 1/2:12 64.23 69.49 91.87 102.92
FL-207 11" 10'-2" 30 1/2" 20.91# 2 9/16-4:12 66.81 72.40 95.99 107.57

NOTE: For use with 9" ventilator only - 32" peak purlin spacing.

RIDGE FLASHING FLOATING

Specify Roof Pitch

FL-200 3 1/2" 10'-2" 15 1/2" 10.63# 1/2-3 3/4:12 41.33 43.07 55.13 61.76
FL-202 4 1/2" 10'-2" 17 1/2" 12.00# 3 13/16-6:12 44.72 47.01 60.58 67.92

NOTE: For use without vent material-18" peak purlin spacing.

FL-213 6 1/2" 10'-2" 21 1/2" 14.74# 1/2-3 3/4:12 50.53 53.72 70.42 79.66
FL-214 7 1/2" 10'-2" 23 1/2" 16.17# 3 13/16-6:12 54.08 57.82 75.98 85.90

NOTE: For use without ventilator - 24" peak purlin spacing.

RIDGE FLASHING
FOR PLASTIC VENT


Specify Roof Pitch

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-300 4 1/2" 10'-2" 19 1/2" 13.37# 1/2-3 3/4:12 51.39 53.79 68.85 77.14
FL-302 5 1/2" 10'-2" 21 1/2" 14.74# 3 13/16-6:12 54.78 57.74 74.30 83.29

NOTE: For use with plastic vent material—18" peak purlin spacing.

FL-303 7 1/2" 10'-2" 25 1/2" 18.37# 1/2-3 3/4:12

60.57

64.44

84.17

95.04

FL304 8 1/2" 10'-2" 27 1/2" 19.74# 3 13/16-6:12 64.04 68.54 89.66 101.18

NOTE: For use with plastic vent material—24" peak purlin spacing.

RIDGE/HIP FLASHING

Specify Roof Pitch

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-209 6" 10'-2" 13" 8.91# 1/2-3 3/4:12 30.48 32.59 42.59 47.72
FL-211 7" 10'-2" 15" 10.28# 3 13/16-6:12 33.95 36.53 48.04 53.89

NOTE: For use without vent material-18" peak purlin spacing.

FL-212 11 1/2" 10'-2" 24" 15.88# 1/2-3 3/4:12

55.75

54.51

73.67 83.52

NOTE: For use without vent material—24" peak purlin spacing.

RIDGE FLASHING
FOR METAL VENT


Specify Roof Pitch

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-540 5 1/2" 10'-2" 22 1/4" 14.92# 1/2-3:12 55.75 58.76 75.95 85.10
FL-541 6" 10'-2" 23 1/4" 15.64# 3 1/8-5:12 57.28 60.58 78.56 88.03

NOTE: For use with metal vent—18" peak purlin spacing.

FL-543 8 1/2" 10'-2" 28 1/4" 18.94# 1/2-3:12 65.02 69.49 91.32 102.92
FL-544 9" 10'-2" 29 1/4" 19.67# 3 1/8-5:12

66.55

71.29

93.93

105.83

NOTE: For use with metal vent—24" peak purlin spacing.

RIDGE FLASHING

Specify Roof Pitch

PART
NUMBER

DIM.
"A"
LENGTH GIRTH WEIGHT ROOF
PITCH

Galvalume
Plus®

Signature®

300
Metallic

200

300

FL-545 8 7/8" 10'-2" 21 1/2" 14.74# 1/2-3:12 46.76 50.72 67.36 75.49
FL-546 9 1/2" 10'-2" 22 3/4" 15.37# 3 1/8-5:12 48.64 53.02 70.60 79.11

NOTE: For use with metal vent—18" peak purlin spacing.

FL-547 11 7/8" 10'-2" 27 1/2" 18.85# 1/2-3:12 56.04 61.51 82.81 93.14
FL-548 12 1/2" 10'-2" 28 3/4" 19.42# 3 1/8-5:12

57.91

63.81

86.04 96.79

NOTE: For use with metal vent—24" peak purlin spacing.

Signature is a registered trademark of Metal Building Components, L.P. Galvalume Plus is a registered and protected trademark of BIEC International, Inc.
Consult the ASBC TECHNICAL MANUAL for proper product application, design details, and other product information.