Double-LokŪ ENGINEERING

Double-LokŪ PANEL
12" Coverage

SECTION PROPERTIES

 

TOP FLAT IN COMPRESSION

BOTTOM FLAT IN COMPRESSION

PANEL GAUGE

Fy
(KSI)

WEIGHT (PSF)

Ix
(in. 4/ft.)
Sx
(in.3/ft.)

Ma
(Kip in.)

Ix
(in.4/ft.)

Sx
(in.3/ft.)

Ma
(KIp in.)

24

50

1.48

0.1759

0.1036

3.1030

0.1052

0.0966

2.8910

22

50

1.86 0.2337

0.1419

4.2476

0.1430

0.1348

4.0363

NOTES

  1. All calculations for the properties of Double-LokŪ panels are calculated in accordance with the 1986 edition of Specifications for the Design of Light Gauge Cold Formed Steel Structural Members - published by the American Iron and Steel Institute (A.I.S.I.).
  2. Ix is for deflection determination.
  3. Sx is for bending.
  4. Ma is allowable bending moment.
  5. All values are for one foot of panel width.
  6. Contact ASBC for wind uplift values.