Table of Contents(Page DL-7)

Double-LokŪ ENGINEERING

Double-LokŪ PANEL
18" Coverage

SECTION PROPERTIES

 

TOP FLAT IN COMPRESSION

BOTTOM FLAT IN COMPRESSION

PANEL
GAUGE

Fy
(KSI)

WEIGHT
(PSF)

Ix
(in.4/ft.)

Sx
(in. 3/ft..)

Ma
(Kip in.)

Ix
(in.4/ft.)

Sx
(in.3/ft.)

Ma
(Kip in.)

24

50

1.32

0.2247

0.1227

3.6746

0.0703

0.0646

1.9344

22

50

1.66

0.3158

0.1886

5.6456

0.0958

0.0904

2.7070

NOTES

  1. All calculations for the properties of Double-LokŪ panels are calculated in accordance with the 1986 edition of Specifications for the Design of Light Gauge Cold Formed Steel Structural Members - published by the American Iron and Steel Institute (A.I.S.I.).
  2. Ix is for deflection determination.
  3. Sx is for bending.
  4. Ma is allowable bending moment.
  5. All values are for one foot of panel width.
  6. Contact ASBC for wind uplift values.

Back   Next