Table of Contents(Page DL-60)

Double-LokŪ SPECIAL ERECTION TECHNIQUES
MID SLOPE FIXED
CONDITION

NOTES

  1. This special detail is for use when a panel run exceeds the thermal movement capabilities of the panel clip. Please refer to page DL-3.
  2. A positive panel attachment is made at the mid-point in the panel run allowing for thermal movement to the eave and ridge.
  3. The standard floating ridge condition must be used in conjunction with this special eave detail.
  4. The floating eave plate must be used to allow for panel movement at the eave.
  5. Floating clips have a maximum movement of 1" in each direction. Articulating clips have a maximum movement of 1 1/4" in each direction. Thermal calculations must be performed for each project to ensure that the thermal movement of the roof will not exceed the design of the clips and slot in the special eave plate.

Back   Next