Double-LokŪ SPECIAL ERECTION
TECHNIQUES
MID SLOPE FIXED
CONDITION
NOTES
- This special detail is for use when a panel run exceeds the thermal
movement capabilities of the panel clip. Please refer to page DL-3.
- A positive panel attachment is made at the mid-point in the panel run
allowing for thermal movement to the eave and ridge.
- The standard floating ridge condition must be used in conjunction with
this special eave detail.
- The floating eave plate must be used to allow for panel movement at the
eave.
- Floating clips have a maximum movement of 1" in each direction.
Articulating clips have a maximum movement of 1 1/4" in each direction.
Thermal calculations must be performed for each project to ensure that the
thermal movement of the roof will not exceed the design of the clips and
slot in the special eave plate.
Back Next