| Table of Contents(Page DL-51) |
Double-LokŪ ERECTION SEQUENCE
Step 16
|
|
|
|
RIDGE-OUTSIDE Apply Tri-Bead tape sealer to the top of the outside closure. Install the ridge flashing starting and ending 2 1/2" outside the steel line. Fasten the ridge flashing to the outside closures with Fastener #4. Install a fastener 1 1/2" from panel seam on both sides of panel. Install additional fasteners directly above minor ribs of panel. Four fasteners are required at each panel. Leave 6" unfastened on each end to allow for the rake trim to be installed later. DO NOT FASTEN THROUGH THE LOCK OF THE STANDING SEAM. For floating peak box installation see page DL-70. |