Table of Contents(Page DL-36)

Double-LokŪ ERECTION SEQUENCE
Step 5

FIELD MODIFY
(FIRST RUN ONLY)

LOW SYSTEM HIGH SYSTEM

BACK-UP PLATE*

NOTE

All back-up plates on first panel run will require field modification to avoid fouling rake support.

Slide a back-up plate onto end of panel; make sure the teeth on top of the back up plate are on top of the panel. Visually check to see that the holes in the panel align with the holes in the back-up plate.

Place Tri-Bead tape sealer over the entire width of the panel. It must be centered directly over the pre-punched holes, following the panel configuration.

CAUTION

Forcing the tape sealer back into the corners will lessen the thickness of the tape sealer where it is needed most
*protected by U.S. Patent No. 4,655,020

Back   Next