| Table of Contents(Page DL-16) |
Double-Lok® SPECIFICATIONS
| G.
Submit roof curb manufacturer’s shop drawings to metal roof system
manufacturer for approval before fabrication of curbs.
2.05 PREFABRICATED ROOF JACKS A. Pipe flashings shall be a one piece [# choose one: EPDM (ethylene propylene diene monomer) molded rubber boot having a serviceable temperature range of -60°F to 270°F (for standard applications) or neoprene molded rubber boot having a serviceable temperature range of -45°F to 250°F (for exposure to petrochemicals) or silicone molded rubber boot having a serviceable temperature range of -100°F to 450°F (for high temperature applications)] and shall be resistant to ozone and ultraviolet rays. Units shall have an aluminum flanged base ring. Do not install pipe flashings through any panel seams - install ONLY in the flat portion of the panel. PART 3- EXECUTION A. Examination: B. Discrepancies: 3.02 INSTALLATION A. Install metal roof system so that it
is weather tight, without waves, warps, buckles, fastening stresses or
distortion, allowing for expansion and contraction. 3.03 ROOF CURB INSTALLATION A. Comply with metal roof system manufacturer’s approved shop drawings, instructions and recommendations for installation of roof curbs. Refer to metal roof system manufacturer’s standard installation details. Anchor curbs securely in place with provisions for thermal and structural movement. |
3.04 CLEANING, PROTECTION A. Dispose of excess materials and
remove debris from site. END OF SECTION DISCLAIMER: ASBC makes no warranty, express or implied, as to the merchantability or fitness for any particular purpose of any product manufactured by an optional manufacturer. If you choose to use a product manufactured by an optional manufacturer, as defined herein, you take the product as is and at your own risk. Descriptions and specifications contained herein were in effect at the time this publication was approved for printing. ASBC reserves the right to discontinue products at any time or change specifications and/or designs without notice and without incurring obligation. |